1
|
# $FreeBSD: src/etc/gettytab,v 1.22 2004/06/06 11:46:27 schweikh Exp $
|
2
|
# from: @(#)gettytab 5.14 (Berkeley) 3/27/91
|
3
|
#
|
4
|
# Most of the table entries here are just copies of the old getty table,
|
5
|
# it is by no means certain, or even likely, that any of them are optimal
|
6
|
# for any purpose whatever. Nor is it likely that more than a couple are
|
7
|
# even correct.
|
8
|
#
|
9
|
# The default gettytab entry, used to set defaults for all other
|
10
|
# entries, and in cases where getty is called with no table name.
|
11
|
#
|
12
|
# cb, ce and ck are desirable on most crt's. The non-crt entries need to
|
13
|
# be changed to turn them off (:cb@:ce@:ck@:).
|
14
|
#
|
15
|
# lc should always be on; it's a remainder of some stone age when there
|
16
|
# have been terminals around not being able of handling lower-case
|
17
|
# characters. Those terminals aren't supported any longer, but getty is
|
18
|
# `smart' about them by default.
|
19
|
#
|
20
|
# Parity defaults to even, but the Pc entry and all the `std' entries
|
21
|
# specify no parity. The different parities are:
|
22
|
# (none): same as ep for getty. login will use terminal as is.
|
23
|
# ep: getty will use raw mode (cs8 -parenb) (unless rw is set) and
|
24
|
# fake parity. login will use even parity (cs7 parenb -parodd).
|
25
|
# op: same as ep except odd parity (cs7 parenb parodd) for login.
|
26
|
# getty will fake odd parity as well.
|
27
|
# ap: same as ep except -inpck instead of inpck for login.
|
28
|
# ap overrides op and ep.
|
29
|
# np: 1. don't fake parity in getty. The fake parity garbles
|
30
|
# characters on non-terminals (like pccons) that don't
|
31
|
# support parity. It would probably better for getty not to
|
32
|
# try to fake parity. It could just use cbreak mode so as
|
33
|
# not to force cs8 and let the hardware handle the parity.
|
34
|
# login has to be rely on the hardware anyway.
|
35
|
# 2. set cs8 -parenb -istrip -inpck.
|
36
|
# ep:op: same as ap.
|
37
|
#
|
38
|
default:\
|
39
|
::cb:ce:ck:lc:fd#1000:im=\r\n%s/%m (%h) (%t)\r\n\r\n:sp#1200:\
|
40
|
:if=/etc/issue:
|
41
|
|
42
|
#
|
43
|
# Fixed speed entries
|
44
|
#
|
45
|
# The "std.NNN" names are known to the special case
|
46
|
# portselector code in getty, however they can
|
47
|
# be assigned to any table desired.
|
48
|
# The "NNN-baud" names are known to the special case
|
49
|
# autobaud code in getty, and likewise can
|
50
|
# be assigned to any table desired (hopefully the same speed).
|
51
|
#
|
52
|
a|std.110|110-baud:\
|
53
|
:np:nd#1:cd#1:uc:sp#110:
|
54
|
b|std.134|134.5-baud:\
|
55
|
:np:nd#1:cd#2:ff#1:td#1:sp#134:ht:nl:
|
56
|
1|std.150|150-baud:\
|
57
|
:np:nd#1:cd#2:td#1:fd#1:sp#150:ht:nl:lm=\E\72\6\6\17login\72 :
|
58
|
c|std.300|300-baud:\
|
59
|
:np:nd#1:cd#1:sp#300:
|
60
|
d|std.600|600-baud:\
|
61
|
:np:nd#1:cd#1:sp#600:
|
62
|
f|std.1200|1200-baud:\
|
63
|
:np:fd#1:sp#1200:
|
64
|
6|std.2400|2400-baud:\
|
65
|
:np:sp#2400:
|
66
|
7|std.4800|4800-baud:\
|
67
|
:np:sp#4800:
|
68
|
2|std.9600|9600-baud:\
|
69
|
:np:sp#9600:
|
70
|
g|std.19200|19200-baud:\
|
71
|
:np:sp#19200:
|
72
|
std.38400|38400-baud:\
|
73
|
:np:sp#38400:
|
74
|
std.57600|57600-baud:\
|
75
|
:np:sp#57600:
|
76
|
std.115200|115200-baud:\
|
77
|
:np:sp#115200:
|
78
|
std.230400|230400-baud:\
|
79
|
:np:sp#230400:
|
80
|
|
81
|
#
|
82
|
# Entry specifying explicit device settings. See termios(4) and
|
83
|
# /usr/include/termios.h, too. The entry forces the tty into
|
84
|
# CLOCAL mode (so no DCD is required), and uses Xon/Xoff flow control.
|
85
|
#
|
86
|
# cflags: CLOCAL | HUPCL | CREAD | CS8
|
87
|
# oflags: OPOST | ONLCR | OXTABS
|
88
|
# iflags: IXOFF | IXON | ICRNL | IGNPAR
|
89
|
# lflags: IEXTEN | ICANON | ISIG | ECHOCTL | ECHO | ECHOK | ECHOE | ECHOKE
|
90
|
#
|
91
|
# The `0' flags don't have input enabled. The `1' flags don't echo.
|
92
|
# (Echoing is done inside getty itself.)
|
93
|
#
|
94
|
local.9600|CLOCAL tty @ 9600 Bd:\
|
95
|
:c0#0x0000c300:c1#0x0000cb00:c2#0x0000cb00:\
|
96
|
:o0#0x00000007:o1#0x00000002:o2#0x00000007:\
|
97
|
:i0#0x00000704:i1#0x00000000:i2#0x00000704:\
|
98
|
:l0#0x000005cf:l1#0x00000000:l2#0x000005cf:\
|
99
|
:sp#9600:
|
100
|
|
101
|
#
|
102
|
# Dial in rotary tables, speed selection via 'break'
|
103
|
#
|
104
|
0|d300|Dial-300:\
|
105
|
:nx=d1200:cd#2:sp#300:
|
106
|
d1200|Dial-1200:\
|
107
|
:nx=d150:fd#1:sp#1200:
|
108
|
d150|Dial-150:\
|
109
|
:nx=d110:lm@:tc=150-baud:
|
110
|
d110|Dial-110:\
|
111
|
:nx=d300:tc=300-baud:
|
112
|
|
113
|
#
|
114
|
# Fast dialup terminals, 2400/1200/300 rotary (can start either way)
|
115
|
#
|
116
|
D2400|d2400|Fast-Dial-2400:\
|
117
|
:nx=D1200:tc=2400-baud:
|
118
|
3|D1200|Fast-Dial-1200:\
|
119
|
:nx=D300:tc=1200-baud:
|
120
|
5|D300|Fast-Dial-300:\
|
121
|
:nx=D2400:tc=300-baud:
|
122
|
|
123
|
#
|
124
|
#telebit (19200)
|
125
|
#
|
126
|
t19200:\
|
127
|
:nx=t2400:tc=19200-baud:
|
128
|
t2400:\
|
129
|
:nx=t1200:tc=2400-baud:
|
130
|
t1200:\
|
131
|
:nx=t19200:tc=1200-baud:
|
132
|
|
133
|
#
|
134
|
#telebit (9600)
|
135
|
#
|
136
|
t9600:\
|
137
|
:nx=t2400a:tc=9600-baud:
|
138
|
t2400a:\
|
139
|
:nx=t1200a:tc=2400-baud:
|
140
|
t1200a:\
|
141
|
:nx=t9600:tc=1200-baud:
|
142
|
|
143
|
#
|
144
|
# Odd special case terminals
|
145
|
#
|
146
|
-|tty33|asr33|Pity the poor user of this beast:\
|
147
|
:tc=110-baud:
|
148
|
|
149
|
4|Console|Console Decwriter II:\
|
150
|
:nd@:cd@:rw:tc=300-baud:
|
151
|
|
152
|
e|Console-1200|Console Decwriter III:\
|
153
|
:fd@:nd@:cd@:rw:tc=1200-baud:
|
154
|
|
155
|
i|Interdata console:\
|
156
|
:uc:sp#0:
|
157
|
|
158
|
l|lsi chess terminal:\
|
159
|
:sp#300:
|
160
|
|
161
|
X|Xwindow|X window system:\
|
162
|
:fd@:nd@:cd@:rw:sp#9600:
|
163
|
|
164
|
P|Pc|Pc console:\
|
165
|
:ht:np:sp#115200:al=root:
|
166
|
|
167
|
bootupcli:\
|
168
|
tc=std.9600:\
|
169
|
:ht:np:sp#115200:al=root:
|
170
|
|
171
|
#
|
172
|
# Wierdo special case for fast crt's with hardcopy devices
|
173
|
#
|
174
|
8|T9600|CRT with hardcopy:\
|
175
|
:nx=T300:tc=9600-baud:
|
176
|
9|T300|CRT with hardcopy (300):\
|
177
|
:nx=T9600:tc=300-baud:
|
178
|
|
179
|
#
|
180
|
# Plugboard, and misc other terminals
|
181
|
#
|
182
|
plug-9600|Plugboard-9600:\
|
183
|
:pf#1:tc=9600-baud:
|
184
|
p|P9600|Plugboard-9600-rotary:\
|
185
|
:pf#1:nx=P300:tc=9600-baud:
|
186
|
q|P300|Plugboard-300:\
|
187
|
:pf#1:nx=P1200:tc=300-baud:
|
188
|
r|P1200|Plugboard-1200:\
|
189
|
:pf#1:nx=P9600:tc=1200-baud:
|
190
|
|
191
|
#
|
192
|
# XXXX Port selector
|
193
|
#
|
194
|
s|DSW|Port Selector:\
|
195
|
:ps:sp#2400:
|
196
|
|
197
|
#
|
198
|
# Auto-baud speed detect entry for Micom 600.
|
199
|
# Special code in getty will switch this out
|
200
|
# to one of the NNN-baud entries.
|
201
|
#
|
202
|
A|Auto-baud:\
|
203
|
:ab:sp#2400:f0#040:
|
204
|
|
205
|
#
|
206
|
# autologin - automatically log in as root
|
207
|
#
|
208
|
|
209
|
autologin|al.9600:\
|
210
|
::tc=std.9600:
|
211
|
|
212
|
#
|
213
|
# Entries for 3-wire serial terminals. These don't supply carrier, so
|
214
|
# clocal needs to be set, and crtscts needs to be unset.
|
215
|
#
|
216
|
3wire.9600|9600-3wire:\
|
217
|
:np:nc:sp#9600:
|
218
|
3wire.38400|38400-3wire:\
|
219
|
:np:nc:sp#38400:
|
220
|
3wire.57600|57600-3wire:\
|
221
|
:np:nc:sp#57600:
|
222
|
3wire.115200|115200-3wire:\
|
223
|
:np:nc:sp#115200:
|
224
|
3wire.230400|230400-3wire:\
|
225
|
:np:nc:sp#230400:
|